Size

96 Tests

Catalog no.

EKU07388

Price

885 EUR

Assay Time:

3 hours

Shipping Conditions:

Ice packs

Sensitivity:

0.054 ng/mL

Detection Method:

Colorimetric

Detection Range:

0.156-10 ng/mL

Estimated Turnaround Time:

6-11 Business days

Research Area:

Signal transduction

Species Reactivity:

Homo sapiens (Human)

Assay Type:

Double-antibody Sandwich

Target Name:

Sodium/Hydrogen Exchanger 1

Storage Temperature:

Short term: 4°C; Long term: see manual.

Application:

For research use only. Not for diagnostic procedures.

Sample Type:

Tissue homogenates, Cell lysates and other biological fluids

Test:

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Precaution of Use:

The Stop Solution is acidic. Do not allow to contact skin or eyes.

Shelf life:

Use Human Sodium/Hydrogen Exchanger 1 (NHE1) ELISA Kit before 8 months

Quality Systems:

The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Specificity:

This assay has high sensitivity and excellent specificity for detection of Sodium/Hydrogen Exchanger 1

Cross Activity:

No significant cross-reactivity or interference between Sodium/Hydrogen Exchanger 1 and analogues was observed.

Test Principle:

No significant cross-reactivity or interference between Sodium/Hydrogen Exchanger 1 and analogues was observed.

Target's alterntive name:

SLC9A1, APNH, Solute Carrier Family 9 Member 1, Sodium/Hydrogen Exchanger, Antiporter, Na+/H+, Amiloride Sensitive, Na (+)/H (+) antiporter, amiloride-sensitive

Precision:

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sodium/Hydrogen Exchanger 1 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sodium/Hydrogen Exchanger 1 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV

Stability:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Properties:

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.