96 Tests
EKU07389
948 EUR
Assay Time:
3 hours
Shipping Conditions:
Ice packs
Sensitivity:
0.126 ng/mL
Detection Method:
Colorimetric
Detection Range:
0.312-20 ng/mL
Latin name:
Rattus norvegicus
Estimated Turnaround Time:
6-11 Business days
Research Area:
Signal transduction
Species Reactivity:
Rattus norvegicus (Rat)
Assay Type:
Double-antibody Sandwich
Target Name:
Sodium/Hydrogen Exchanger 3
Storage Temperature:
Short term: 4°C; Long term: see manual.
Application:
For research use only. Not for diagnostic procedures.
Test:
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Sample Type:
Tissue homogenates, Cell lysates and other biological fluids.
Precaution of Use:
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Shelf life:
Use Rat Sodium/Hydrogen Exchanger 3 (NHE3) ELISA Kit before 8 months
Quality Systems:
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Target's alterntive name:
SLC9A3, Solute Carrier Family 9 Member 3, Sodium-hydrogen antiporter 3, Na (+)/H (+) exchanger 3
Specificity:
This assay has high sensitivity and excellent specificity for detection of Sodium/Hydrogen Exchanger 3
Cross Activity:
No significant cross-reactivity or interference between Sodium/Hydrogen Exchanger 3 and analogues was observed.
Test Principle:
No significant cross-reactivity or interference between Sodium/Hydrogen Exchanger 3 and analogues was observed.
Properties:
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
About:
Rats are used to make rat monoclonal anti mouse antibodies. There are less rat- than mouse clones however. Rats genes from rodents of the genus Rattus norvegicus are often studied in vivo as a model of human genes in Sprague-Dawley or Wistar rats.
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sodium/Hydrogen Exchanger 3 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sodium/Hydrogen Exchanger 3 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.